Quantitative analysis of fine needle aspiration biopsy samples

Authors

  • Mirjana Rajer
  • Marko Kmet

Abstract

Background. The fine needle aspiration biopsy (FNAB) is one of the methods used in tumour evaluation. Since a certain number of tumour cells are needed for a complete diagnostic algorithm, we wanted to test how many cells remain in the needle and syringe after routine stains have been made and which factors influence this number. The remaining cells are used in ancillary diagnostic procedures.

Materials and methods. One hundred fifty two FNAB samples of tumours of the breast, thyroid and lymph nodes were included in our study. We counted the cells which were left in the needle and the syringe after the standard smears had been made. Buerker-Tuerk’s chamber was used for this purpose.

Results. The number of cells depended on the organ from which the cells had been aspirated, on the type of tumour and, in the case of breast cancer, also on the level of experience of the FNAB performer. The percentage of samples with too few cells for all modern diagnostic methods (<5x105 ) is lowest in FNAB of lymph nodes (4.9%), followed by breast (16.7%) and thyroid (18%).

Conclusions. We concluded that FNAB in the majority of cases grants a sufficient number of cells for the standard microscopic evaluation and also ancillary diagnostic procedures.

Downloads

Published

2005-12-01

How to Cite

Rajer, M., & Kmet, M. (2005). Quantitative analysis of fine needle aspiration biopsy samples. Radiology and Oncology, 39(4). Retrieved from https://www.radioloncol.com/index.php/ro/article/view/1284

Issue

Section

Clinical oncology